The Intellect-69PM2 is a process monitor that accepts analog signal inputs and has a 1/2 digits of bright, 7-segment LED displays. The unit can be field programmed to accept 0-20mA, 4-20mA, 0-5V, 0-10V or 1-5V signals.
featuring 4
Two assignable setpoints are standard for high/low alarm outputs. The high and low scaling settings (-9999 to 49999) are programmable from the front panel. By pressing the “view” button, the unit will display process reading, peak or valley.
Press the lock button once to freeze the display, press it again to resume normal operation. Press the lock button 4 times quickly to enter lock code for panel lockout. RS-232, RS-422 and 4-20mA analog out are available options for interfacing to a host computer or strip chart recorder.

Feature

  • Analog Input 0-20 mA, 4-20 mA 0-5V, 0-10V or 1-5V
  • Display Rate, Pressure, Level, Temperature, Watts, etc., Peak & Valley
  • Calibration, High and Low Values (-9999 to 49999) Fully Programmable Through Keypad
  • NEMA 4X / IP65 Front
  • +24V Output for Peripherals
  • 16 Bit A/D Resolution
  • 2 Form C SPDT Relays (optional)
  • 2 Levels of Operator Password Lockout

Application

Any process monitoring application where two set points and scaling are needed.

Specification

Display41/2 digit, .55” high, 7 segments, red-orange, LED.
Input Power110, 220 VAC ± 15% or 12 to 24VDC.
Current:300 max. mA DC or 10.0 VA (10W) at rated AC voltage.
Output Power(AC powered units only) + 24VDC @ 50mA regulated ±5%. (100 mA available on request)
TemperatureOperating: +32°F (0°C) to +130°F (+54°C).
Storage: -40°F (-40°C) to +200°F (93°C).
MemoryEEPROM stores data for ten years if power is lost.
ResetFront Panel: resets displayed value and control outputs.
Control OutputsStandard: Open collector sinks 250mA from 30VDC when active.
Optional: 2 each Form C SPDT 5 Amp @ 120/240 VAC or 28 VDC.
InputLinear 0-20mA, 4-20mA, 0-5V, 0-10V or 1-5V se-lectable from the front panel.
CalibrationThe unit does all of the calibrations internally. There are no potentiometers to adjust and the unit never needs to be removed from the case or panel.
Set PointsTwo control setpoints are provided. The unit comes standard with two open collector control outputs. Two 5 Amp, Form C relays are optional. The outputs have a programmable alarm range from -9999 to 49999 with hysteresis.
Process DisplayUpdates 4 times per second, accurate to 4.5 digits.
ProgrammingDecimal points, Scaling from -9999 to 49999, setpoints, input type, and security lock code are all programmable from the front panel.
HousingStandard 1/8 DIN, high impact ABS plastic case (NEMA 4X/IP65 front panel).
Shipping Weight2 lbs.
Overvoltage Protection50 V
Over-current Protection50 mA
Temperature StabilityWill not drift more than 10 parts per million per °C from 0°C to 54°C
Accuracy1% (5 V inputs .16%)
ListingCE Compliant, CSA (File No. LR91109), NRTL/C pending