sponsor

sponsor

Slider

Recent Flow

Magnetic flow meter

Installasi flow meter

Digital Flow Sensor

Flow meter

ULTRASONIC FLOW METER

Flow meter Air Limbah

» » » » » » » Fluidwell F014 Flow Rate Indicator

F014 Intrinsically Safe – Flow rate Indicator / Totalizer with pulse output

The F014 is a local indicator/transmitter which displays the actual flow rate, total and accumulated total. A scaled pulse, related to the accumulated total is generated for re-transmitting the count on the display. The total can be reset to zero by pressing the CLEAR button twice. The accumulated total can register up to 11 digits and is backed-up in EEPROM memory every minute, just as the running total.
On-screen engineering units are easily configured from a comprehensive selection.

Advantages

  • Robust aluminum or stainless steel 316L field enclosure (IP66, IP67 / NEMA Type4X).
    It is so rugged, a truck can even stand on it!
  • Intrinsically Safe available – ATEX, IECEx, FM and CSA approval for gas and dust applications.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.
  • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors.

Feature

  • Scaled pulse output reflecting the accumulated total.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Displays total and flow rate simultaneously.
  • GRP, Aluminum or high-grade stainless steel enclosure.
  • Accumulated total – not resettable: eleven 8mm (0.31″) digits.
  • Flow rate: seven 17mm (0.67″) or 8mm (0.31″) digits.
  • Total – resettable: seven 17mm (0.67″) digits.
  • Separate engineering units for flow rate and total.
  • Large digit selection for flow rate or total.
  • Intrinsically safe according to ATEX, IECEx, FM and CSA C-US.
  • Selectable on-screen engineering units for flow rate: mL, L, m³, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm³, NL, P or no unit.
  • Selectable on-screen time units for flow rate: /sec, /min, /hour or /day.
  • Selectable on-screen engineering units for total: ml, L, m³, GAL, USGAL, kg, lb, bbl or no unit.
  • LED backlight with adjustable intensity.
  • Auto backup of settings and running totals in EEPROM memory.
  • Easy configuration with clear alphanumerical display.
  • Various accessories are available for this product

Application

  • Flow measurement where re-transmission of the totalizer function is required.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).
  Another Article:

Specification

Signal Inputs

  • Flowmeter Inputs

    • Pulse-type inputs:
      Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
    • (0)4 – 20mA.

Signal Outputs

  • Pulse outputs

    • Function: Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons).
      Max. frequency: 500Hz.
      Adjustable pulse length from 1 msec. to 10 seconds.
    • Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay.
  • Alarm outputs

    • None
  • Analog outputs

    • None.

Supply

  • Power Supply

    • Long-life Lithium battery.
    • 4 – 20mA, input Loop-powered.
    • 8 – 24V AC/DC.
    • 115 – 230V AC.
    • Basic: 8 – 30V DC.
  • Sensor Supply

    • 3.2, 8.2, 12, 24V DC.

Hazardous Area

  • Intrinsically Safe

    • ATEX:
      Gas: II 1 G Ex ia IIC T4 Ga
      Dust: II 1 D Ex ia IIIC T100°C Da
    • IECEx:
      Gas: Ex ia IIC T4 Ga
      Dust: Ex ia IIIC T100°C Da
    • CSA:
      I.S. Class I/II/III, Div 1, Grp A…G, T4 Class I, Zone 0, AEx ia IIC T4
    • FM:
      I.S. Class I/II/III, Div 1, Grp A…G, T4 Class I, Zone 0, AEx ia IIC T4
  • Explosion Proof

    • ATEX: 
      Gas: II 2 G / Ex d IIB T5 Gb
      Dust: II 2 D / Ex t IIIB T100°C Db
  • Communication

    • Modbus communication is available on F1-Series products.
    • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.

 More information please Email Marketing@wmablog.com

«
Next
Posting Lebih Baru
»
Previous
Posting Lama

Tidak ada komentar:

Most Wanted

Top Article

Flowmeter Ultrasonic

Flowmeter ultrasonic  adalah jenis    flow meter yang prinsip kerjanya mengukur  kecepatan aliran suatu fluida dengan menggunakan ultra so...