sponsor

sponsor

Slider

Recent Flow

Magnetic flow meter

Installasi flow meter

Digital Flow Sensor

Flow meter

ULTRASONIC FLOW METER

Flow meter Air Limbah

» » » » Electromagnetic Flow Converter

 ALIA ELECTROMAGNETIC FLOW METER

AMC2100E series Converter With temperature/energy function can be used with AMF seriesflowmeter in both compact or separate versions.

FEATURES

 Four line LCD display Flowrate/Energy/Totalizer
 Accuracy of +/-0.4% of reading
 Bi-directional flow measurement, current and pulse output
 Large digital display, With temperature/energy function
 99 times records for power on/off
 MODBUS/HART communication

SPECIFICATION

Excitat
Excitation:Keyboard:
Square wave4 keys from external for programming 
Display:and display control.
4 lines LCD with backlightLow Flow Cutoff:
Line 10 to 9.9 %
Date and TimeDatalogger Function:
Line 299 times records for power on/off
6 digit flowrateRecord Data:
7 digit energy valueDate/Time when Power on/off
Fault code 99 years flow rate/energy/
Supply temperatureTemperature / Total flow / Total energy
Line 3One Record Data per Hour
9 digit totalizer for forwarding/ reverse flowDamping:
9 digit totalizer for heat / cold  energy0.1 to 99.9 Second
Fault code contentSelf Diagnosis:
Return temperatureThe following error message is 
Line 4indicated during application
Differential temperature– Coil fail
Unit– Power fail
L/S, L/M, L/H, M3/S, M3/L, M3/H– Output overaged
KW, MW, KJ/H, MJ/H, GJ/H – Internal error
Measuring Range:– Overflow
Min.  0 to 0.15 m/s– Empty pipe
Max. 0 to 15 m/sCable Entry:
Accuracy:PG11
+/-0.4% of reading (Velocity >= 0.5 m/s)Protection Class:
+/-0.002 m/s (Velocity < 0.5 m/s)IP 65
Repeatability:Ambient Temperature:
+/-0.1% of reading-25 to +65 oC
Current Output:Material:
4-20 mA (Isolated)Aluminum Alloy
LoadTemperature Input:
Max. 600 PT1000, 2 wire 
Pulse output:Power Supply:
Open collector90-260 VAC, 50/60 Hz
Rating24 VDC +/- 10% (Option)
3 to 30 VDC, 20 mA Max. Power Consumption:
Pulse Rate:3-17 W (depending on the sensor size)
1)Scale pulse, (Pulse/M3, Pulse/L,
 Other)
Weight:
2)Frequency, 0-5000 Hz1.4 Kg
Communication:Mounting:
RS 485(MODBUS Protocol)Wall mounting
HART signalBracket on 2″ pipe
Data Storage:
Operation parameters and totalization 
figures are stored by EEPROM for more than 10 years



For  More Information please Email : Marketing@wmablog.com




«
Next
Posting Lebih Baru
»
Previous
Posting Lama

Tidak ada komentar:

Most Wanted

Top Article

Flowmeter Ultrasonic

Flowmeter ultrasonic  adalah jenis    flow meter yang prinsip kerjanya mengukur  kecepatan aliran suatu fluida dengan menggunakan ultra so...